OEM-ready dual-resolution syringe core

Dual Resolution Syringe

Nanoliter precision. Hundreds of microliters of range.

Replace a conventional syringe in a compatible drive and give the channel fine differential metering, high-volume operation, and clean contact-free delivery—without adding a second pump.

DRD Dual Resolution Syringe DRS 15/300 for OEM syringe drives
Differential modeFine resolution
Single modeHigh flow
Shown configurationDRS 15/300 · Cavro XP-3000 type drive
15–20 µLDifferential model range
300–340 µLSingle-mode capacity
2 modesFine control + high flow
Contact-freeClean delivery pathway

One syringe, a wider operating envelope

Replace the conventional syringe. Transform the channel.

The Dual Resolution Syringe fits familiar syringe-drive architectures while changing what the channel can do. Its dual-plunger geometry enables accurate low-volume work without surrendering the larger volume and flow rate needed for dilution, mixing, priming, and complete dispensing.

For multichannel and automated liquid handlers, this can consolidate tasks that would otherwise require separate syringe sizes, extra fluidic hardware, or contact-dependent dispensing techniques.

Dual Resolution operation

Fine displacement and delivery force in the same channel.

The two plungers can work together for small net displacement or independently when the application needs a larger stroke and higher flow.

01 Differential mode

Precise low-volume aspiration

The difference between plunger areas creates a small effective displacement while preserving useful mechanical travel for repeatable control.

Designed for microliter and nanoliter work
02 Single mode

Large-volume movement and vigorous flow

Operating a plunger independently unlocks the larger displacement and flow rate needed for rapid filling, dilution, mixing, and priming.

Up to 300–340 µL by model
03 Controlled delivery

Complete contact-free dispensing

Available flow supports clean release without touching the destination, helping reduce carryover and contact-related variability.

Touchless delivery pathway

Model pathway

Match the syringe to the drive architecture.

DRD configurations support common Cavro- and Hamilton-style syringe drives with model-specific plunger interfaces and operating volumes.

Cavro-compatible15 / 300

DRS 15/300

Threaded top plunger designed to fit Cavro XP-3000 type syringe drives. DRD part number 81324-112.

Differential
15 µL
Single mode
300 µL
View Concept Sheet
Hamilton-compatible18 / 340

DRS 18/340

Luer-and-flange top-plunger configuration for Hamilton PSD/4 type syringe-drive architectures.

Differential
18 µL
Single mode
340 µL
View Concept Sheet
Hamilton-compatible20 / 300

DRS 20/300

An alternative Hamilton-style configuration pairing a 20 µL differential range with 300 µL single-mode capacity.

Differential
20 µL
Single mode
300 µL
View Concept Sheet
DRS 15/300 syringes integrated into an eight-channel liquid handler
Five DRS 15/300 units shown in an eight-channel Cavro XP-3000 type liquid handler.

OEM integration example

Five substituted channels. A much larger operating envelope.

In the archived multichannel example, DRS 15/300 units replace conventional syringes directly in existing drives. Each substituted channel gains differential low-volume control, large-volume operation, and contact-free delivery capability.

  • 01
    Familiar mechanical interfaceDesigned around established Cavro- and Hamilton-style drive formats.
  • 02
    Multichannel scalabilityApply the operating range across selected or complete channel sets.
  • 03
    Command-level integrationTechnical documentation supports software and motion-control implementation.
  • 04
    Application flexibilityPrecision aspiration, dilution, mixing, and touchless delivery from one core.
Discuss Your Instrument

Technical resources

Start with the model documents.

Review the archived engineering material, then contact DRD for the current integration manual, command guidance, pricing, and availability.

Product story

See the Dual Resolution concept in motion.

Two archived presentations introduce the syringe embodiment, its operating principle, and its place in the wider DRD platform.

2.75-minute overview

Dual Resolution Syringe Impact Movie

A concise introduction to the syringe embodiment and its unusually wide operating range.

10-minute technical story

DRD Principles, DRS & NEPTUNE96

A deeper presentation covering displacement, TITAN automation, the DRS platform, and NEPTUNE96.